Продукция

QPHY-USB3.1-Tx-Rx

QPHY-USB3.1-Tx-Rx

QPHY-USB3.1-Tx-Rx offers an automated test package for USB 3.1 transmitter and receiver compliance testing, characterization, and debug.
QPHY-BroadR-Reach Automotive Ethernet enables faster data communication to meet the demands of today’s vehicles and the connected vehicles of the future. QPHY-BroadR-Reach automates testing and validation of 100 Mb/s Automotive Ethernet, which is described in both the BroadR-Reach and 100Base-T1 (IEEE 802.3bw) specifications.
ET-PMT Electrical Telecom Mask Test Package
GRL-USB-PD GRL-USB-PD software provides a simple and efficient way to perform USB-PD electrical parametric and protocol measurements. GRL-USB-PD provides waveform visibility and protocol analysis making it ideal for design and debug of USB Type-C Power Delivery silicon and end products.
GRL-USB-PD-C1 GRL-USB-PD-C1 is a flexible test controller, designed for USB-PD Compliance testing of the Unit Under Test (UUT) and more.
QPHY-10GBase-KR The Teledyne LeCroy QPHY-10GBase-KR solution automates testing for 10Gigabite Ethernet Copper Backplane base on the IEEE 802.3ap specifications. The test framework simplifies the test setup and execution of generic and common test requirements such as jitter separation, rise/fall time and transmitter equalization parameters. The guided wizard prompts the user to for specification required patterns and takes the measurements accordingly. The test report includes the test results pass/fail summary, margins and limits, as well as waveforms and measurements used during the test process.
QPHY-10GBASE-T QPHY-10GBASE-T automated compliance test software performs electrical compliance testing of the Physical Media Attachment (PMA) for 10GBASE-T Ethernet PHY, based on IEEE802.3-2008 requirements.
QPHY-DDR2 The Teledyne LeCroy QPHY-DDR2 Test Solution is the best way to characterize DDR2 memory interfaces. Capable of performing measurements on 400 MHz, 533 MHz, 667 MHz, 800 MHz, 1066 MHz and custom speed grades, QPHY-DDR2 has a full suite of Clock, Electrical and Timing tests as specified by the JEDEC Specification and Intel JEDEC Specifications Addendums.
QPHY-DDR3 The Teledyne LeCroy QPHY-DDR3 Test Solution is the best way to characterize DDR3, DDR3L, and LPDDR3 memory interfaces. Capable of performing measurements on 800 MT/s, 1066 MT/s, 1333 MT/s, 1600 MT/s, 1866 MT/s, 2133 MT/s and custom speed grades, QPHY-DDR3 has a full suite of Clock, Electrical, and Timing tests as specified by the JEDEC Specification.
QPHY-DDR4 DDR4 is an evolutionary upgrade from DDR3. It introduces data transfer rates which are nearly double the DDR3 transfer rates, ranging from 1.6 GT/s up to 3.2 GT/s. DDR4's higher transfer rates and lower operating voltage have driven new test methodologies and test requirements which were not previously required for DDR3 in order to ensure proper signal fidelity. QPHY-DDR4 has a full suite of Clock, Electrical, and Timing tests as specified by the JEDEC Specification which will aid in DDR4 design validation.
QPHY-DisplayPort The QPHY-DisplayPort software option provides an automated test environment for running all of the normative real-time oscilloscope tests for sources in accordance with Version 1.2b of the Video Electronics Standards Association (VESA) DisplayPort PHY Compliance Test Specification, as well as tests for HBR3 signals at 8.1 Gbps.
QPHY-eDP QPHY-eDP provides a highly automated and easy-to-use solution for Embedded DisplayPort source testing in accordance with version 1.4 of the VESA Embedded DisplayPort PHY compliance test guideline.
QPHY-ENET Ethernet testing compliant with IEEE 802.3-2005 requires many test setups and connections and mask tests. Using Teledyne LeCroy QualiPHY-ENET these measurements are easy to setup and complete. Instructive connection diagrams and message boxes appear as pop ups on the oscilloscope screen. The connection diagram instructs the user how to change test fixture and jumper pins in order to do complete test. When the tests are complete, QualiPHY will generate a test report in PDF, HTML, or XML formats. Jitter and pulse mask tests are performed with automatic waveform alignment, and all test results feature pass/fail indicators corresponding to the standard being tested.
QPHY-HDMI2 automated and easy-to-use solution for HDMI transmitter testing in accordance with Version 2.0 of the HDMI Compliance Test Specification (including testing for version 1.4 devices).
QPHY-LPDDR2 The Teledyne LeCroy QPHY-LPDDR2 Test Solution is the best way to characterize LPDDR2 memory interfaces. Capable of performing measurements on 466 MHz, 533 MHz, 667 MHz, 800 MHz, 900 Mhz, 1066 MHz and custom speed grades, QPHY-LPDDR2 has a full suite of Clock, Electrical and Timing tests as specified by the JEDEC Specifications.
QPHY-MIPI-DPHY - D-PHY Compliance Package Test Solution provides automated control for Teledyne LeCroy oscilloscopes for performing transmitter physical layer tests as described by the MIPI Alliance Specification for D-PHY version 1.00.00
QPHY-MOST150 The Teledyne LeCroy QPHY-MOST150 compliance test package provides a highly automated and easy-to-use solution to MOST compliance testing. QPHY-MOST150 will perform all electrical compliance tests as defined in the MOST150 oPHY Automotive Physical Layer Sub-Specification Rev. 1.1 and MOST150 cPHY Automotive Physical Layer Sub-Specification Rev 1.0.
QPHY-MOST50 The Teledyne LeCroy QPHY-MOST50 compliance test package provides a highly automated and easy-to-use solution to MOST compliance testing. QPHY-MOST50 will perform all electrical compliance tests as defined in the MOST Electrical Physical Layer Specification Rev. 1.1.
QPHY-PCIe The Teledyne LeCroy QPHY-PCIe Test Solution provides automated control for Teledyne LeCroy oscilloscopes for performing the entire transmitter physical layer tests as described by the Card Electro-mechanical specification Rev 1.1 and 2.0
QPHY-PCIe3 Teledyne LeCroy QPHY-PCIe3 Test Solution provides automated control for Teledyne LeCroy oscilloscopes for performing transmitter physical layer tests as described by the PCI Express Base Specification Revision 3.0 Version 0.9 and the Card Electromechanical Specification Revision 3.0 Version 0.7.
QPHY-SAS2 The Teledyne LeCroy QPHY-SAS2 Test Solution provides automated control for the SDA 8 Zi series of oscilloscopes for performing all of the transmitter physical layer tests as described by version 1.01 of the UNH IOL Serial Attached SCSI (SAS) Consortium SAS-2 6Gb/s Physical Layer Test Suite. This specification covers targets and initiators running at 1.5 Gb/s, 3.0 Gb/s and 6.0 Gb/s.
QPHY-SAS3 The QPHY-SAS3 Test Solution provides automated control of the SDA 8 Zi-A and LabMaster 10 Zi oscilloscopes for performing all of the transmitter physical layer tests as described by the T10 SAS-3 specification. This specification covers targets and initiators running at 1.5 Gb/s, 3.0 Gb/s, 6.0 Gb/s, and 12.0 Gb/s.
QPHY-SATA-TSG-RSG for SATA compliance testing to be used in conjunction with the PeRT3. By leveraging the capabilities of both the oscilloscope and the PeRT3, QPHY-SATA-TSG-RSG can automatically perform all of the PHY, TSG, OOB, and RSG tests as described by the SATA UTD 1.5. Furthermore, QPHY-SATA-TSG can be configured to test Gen1, Gen2, and Gen3 SATA PUTs.
QPHY-SFI The Teledyne LeCroy QPHY-SFI solution automates testing for SFI base on the SFF 8431 specifications. The test framework simplifies the test setup and execution of generic and common test requirements such as jitter separation, rise/fall time and transmitter equalization parameters. The guided wizard prompts the user to for specification required patterns and takes the measurements accordingly. The test report includes the test results pass/fail summary, margins and limits, as well as waveforms and measurements used during the test process.
QPHY-USB The USB package provides a complete acquisition and analysis system for USB 2.0 devices, hosts, and hubs, as specified in the USB-IF USB 2.0 Electrical Test Specification. The test software implements a full set of electrical tests for USB 2.0, including High-, Full-, and Low-speed tests and is supported by Teledyne LeCroy’s QualiPHY automated test and reporting software.
QPHY-USB3-Tx-Rx SuperSpeed USB is one of most highly anticipated standards in several years. At 10x the data rate of USB 2.0 and with new features like CTLE (continuous time linear equalization) and reference channels, SuperSpeed USB will pose new challenges to implementers.
QPHY-USB3.1-Tx-Rx QPHY-USB3.1-Tx-Rx offers an automated test package for USB 3.1 transmitter and receiver compliance testing, characterization, and debug.
Key Features
  • QPHY-USB3.1-Tx-Rx offers fully automated transmitter and receiver testing
  • Support for both Gen1 (5 Gb/s) and Gen2 (10 Gb/s) DUTs
  • Stimulate DUT to change compliance patterns using the PeRT3
  • Automated receiver calibration process reduces complexity and saves time during testing
  • SigTest software is fully integrated into the oscilloscope software
  • QPHY-USB3-Tx-Rx provides full reporting capability including Pass/Fail indications and screenshots from pertinent tests
  • Eye Doctor II Advanced Signal Integrity Tools enable channel emulation and CTLE/DFE equalization
  • SDAIII-CompleteLinQ enables simultaneous analysis of multiple points in the USB 3.1 channel
Automated Tx and Rx Testing

QPHY-USB3.1-Tx-Rx offers a fully automated test package for USB 3.1 transmitter and receiver compliance testing, characterization, and debug. It provides connection diagrams to ensure the proper setup for the required measurements, automates the oscilloscope for performing these measurements, and provides a comprehensive report of results including pass/fail results and screenshots.

Stimulate DUT to Change CPs Using the PeRT3

QPHY-USB3.1-Tx-Rx can control the PeRT3 communication with the DUT on the protocol layer by sending a specific number of Ping.LFPS in order to stimulate it to output the required CPs for each test. This enables fully automated transmitter compliance testing.

Automated Rx Calibration

Receiver test specifications require calibration of the jitter output sources for the test instrument. When using the PeRT3 in conjunction with a Teledyne LeCroy oscilloscope, this calibration is done automatically by the QPHY-USB3.1-Tx-Rx application.

Complete SigTest Integration

SigTest is the official software written by the USB-IF for compliance testing. By integrating SigTest into QPHY-USB3.1-Tx-Rx pre-compliance testing can be confidently performed prior to attending a USB-IF workshop. QPHY will automatically pass waveforms to SigTest and incorporate the results in the complete QualiPHY report.

Advanced Debug Tools

The Eye Doctor II analysis software enables channel emulation and receiver equalization. For testing USB 3.1 at the far end of the channel, a design engineer has the option of using a physical channel or they can use channel emulation to see what their serial data signal would look like if it had been transmitted through the channel. It is possible to experiment with the multiple CTLE and DFE combinations from the USB 3.1 standard or to define a custom CTLE for debugging purposes.

Multi-Point Simultaneous Analysis

SDAIII-CompleteLinQ is capable of simultaneously analyzing multiple lanes. Four “lanes” of analysis are available, allowing users to analyze data streams from different locations in their USB channel(s). For example, Lane 1 can show the Tx output, Lane 2 can show the signal at the far end of an emulated channel, Lane 3 can show the equalized far end signal, and Lane 4 the far end signal with a different CTLE/DFE equalization scheme.